modbus_new_rtu - create a libmodbus context for RTU
Contents
Description
The modbus_new_rtu() function shall allocate and initialize a modbus_t structure to communicate in RTU
mode on a serial line.
The device argument specifies the name of the serial port handled by the OS, eg. "/dev/ttyS0" or
"/dev/ttyUSB0". On Windows, it’s necessary to prepend COM name with "\\.\" for COM number greater than 9,
eg. "\\\\.\\COM10". See http://msdn.microsoft.com/en-us/library/aa365247(v=vs.85).aspx for details
The baud argument specifies the baud rate of the communication, eg. 9600, 19200, 57600, 115200, etc.
The parity argument can have one of the following values
• N for none
• E for even
• O for odd
The data_bits argument specifies the number of bits of data, the allowed values are 5, 6, 7 and 8.
The stop_bits argument specifies the bits of stop, the allowed values are 1 and 2.
Once the modbus_t structure is initialized, you must set the slave of your device with
modbus_set_slave(3) and connect to the serial bus with modbus_connect(3).
Errors
EINVAL
An invalid argument was given.
ENOMEM
Out of memory. Possibly, the application hits its memory limit and/or whole system is running out of
memory.
Example
modbus_t *ctx;
ctx = modbus_new_rtu("/dev/ttyUSB0", 115200, 'N', 8, 1);
if (ctx == NULL) {
fprintf(stderr, "Unable to create the libmodbus context\n");
return -1;
}
modbus_set_slave(ctx, YOUR_DEVICE_ID);
if (modbus_connect(ctx) == -1) {
fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
modbus_free(ctx);
return -1;
}
Name
modbus_new_rtu - create a libmodbus context for RTU
Return Value
The function shall return a pointer to a modbus_t structure if successful. Otherwise it shall return NULL
and set errno to one of the values defined below.
See Also
modbus_new_tcp(3) modbus_free(3)
Synopsis
modbus_t*modbus_new_rtu(constchar*device,intbaud,charparity,intdata_bit,intstop_bit);