modbus_set_response_timeout - set timeout for response
Contents
Description
The modbus_set_response_timeout() function shall set the timeout interval used to wait for a response.
When a byte timeout is set, if elapsed time for the first byte of response is longer than the given
timeout, an ETIMEDOUT error will be raised by the function waiting for a response. When byte timeout is
disabled, the full confirmation response must be received before expiration of the response timeout.
The value of to_usec argument must be in the range 0 to 999999.
Errors
EINVAL
The argument ctx is NULL, or both to_sec and to_usec are zero, or to_usec is larger than 1000000.
Example
uint32_t old_response_to_sec;
uint32_t old_response_to_usec;
/* Save original timeout */
modbus_get_response_timeout(ctx, &old_response_to_sec, &old_response_to_usec);
/* Define a new timeout of 200ms */
modbus_set_response_timeout(ctx, 0, 200000);
Name
modbus_set_response_timeout - set timeout for response
Return Value
The function shall return 0 if successful. Otherwise it shall return -1 and set errno.
See Also
modbus_get_response_timeout(3) modbus_get_byte_timeout(3) modbus_set_byte_timeout(3)
Synopsis
intmodbus_set_response_timeout(modbus_t*ctx,uint32_tto_sec,uint32_tto_usec);