EDS - Embedded Data Systems Sensors
Contents
Addressing
All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:
FamilyCode
8 bits
Address
48 bits
CRC 8 bits
Addressing under OWFS is in hexadecimal, of form:
01.123456789ABC
where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be correct.
Alarm
Show or clear the out-of-range flags. When set, the device will respond to a conditional search. Clearing
the flags is performed with the EDS00XX/alarm/clear command, not just having the measured value return to
the center range.
EDS00XX/alarm/clearwrite-only,yes-no
Write "1" to clear ALL the alarm flags.
EDS00XX/alarm/temp_hiEDS00XX/alarm/temp_lowEDS006X/alarm/humidity_hiEDS006X/alarm/humidity_lowEDS006X/alarm/dew_point_hiEDS006X/alarm/dew_point_lowEDS006X/alarm/heat_index_hiEDS006X/alarm/heat_index_lowEDS006X/alarm/humidex_hiEDS006X/alarm/humidex_lowEDS006X/alarm/pressure_hiEDS006X/alarm/pressure_lowEDS006X/alarm/inHg_hiEDS006X/alarm/inHg_lowEDS006X/alarm/light_hiEDS006X/alarm/light_lowEDS0070/alarm/vib_hiEDS007X/alarm/vib_lowEDS007X/alarm/resistance_hiEDS007X/alarm/resistance_lowEDS0080/alarm/current_hi.[0-7|ALL|BYTE]EDS0080/alarm/current_low.[0-7|ALL|BYTE]EDS0082/alarm/volts_hi.[0-7|ALL|BYTE]EDS0082/alarm/volts_low.[0-7|ALL|BYTE]EDS0083/alarm/current_hi.[0-3|ALL|BYTE]EDS0083/alarm/current_low.[0-3|ALL|BYTE]EDS0085/alarm/volts_hi.[0-3|ALL|BYTE]EDS0085/alarm/volts_low.[0-3|ALL|BYTE]EDS0090/alarm/hi[0-7|ALL]EDS0090/alarm/low[0-7|ALL]read-only,yes-no
Show corresponding out-of-range alarm. "1" means in alarm state. Can only be turned off with clearAlarms
None.
Availability
Counter
EDS00XX/counter/secondsread-only,unsignedinteger
Approximate seconds since power up.
EDS0090/counter/pulses.0-7|ALLread-only,unsignedinteger
Pulses on each channel since power up or reset. Channel should be set to input ( EDS0090/output/set.x =0
)
EDS0090/counter/reset.0-7|ALL|BYTEread-write,yes-no
Clear the pulse count on the corresponding channel.
EDS007X/counter/samplesread-only,unsignedinteger
Approximate samples since power up.
Current
The EDS0080 and EDS0083 measure current in the 4-20mA range, with upper and threshold limits and the
ability to set an alarm and independently trigger a relay if the value is out of range.
EDS0080/current.[0-7|ALL]EDS0083/current.[0-3|ALL]read-only,floatingpoint
Current current level. (4-20mA)
EDS0080/max_current.[0-7|ALL]EDS0080/max_current.[0-3|ALL]EDS0083/min_current.[0-7|ALL]EDS0083/min_current.[0-3|ALL]read-only,floatingpoint
Maximum and minimum current readings since last alarm/clear command.
Datasheet
EDS0064EDS0065EDS0066EDS0067EDS0068
https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vN2E4NGUwMGItMzc5MS00NDNmLTljZGYtN2NmM2Q3YWE5NmVh&hl=en
EDS0070http://www.embeddeddatasystems.com/assets/images/supportFiles/manuals/EN-UserMan%20%20OW-
Vibration%20V01.pdf
EDS0071EDS0072
https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vMjVhNWQzYzItZTRhMi00NGY2LWI4NTQtYjZlYTgzYzY0NmNm&hl=en
EDS0080EDS0083
https://eds.zendesk.com/attachments/token/ulnpj6mvpp6yzwo/?name=EN-USERMAN+OW-IO-AIX-420+v1p0.pdf
EDS0082EDS0085
https://eds.zendesk.com/attachments/token/vyai6ylpw6edala/?name=EN-USERMAN+OW-IO-AIX-10V+v1p0.pdf
EDS0090
8 Discrete I/O
Description
1-Wire1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc.
The bus is a low-power low-speed low-connector scheme where the data line can also provide power.
Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices,
including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data
loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There
are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single busmaster and multiple slaves on the same wire. The bus master initiates
all communication. The slaves can be individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.
OWFSdesignOWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The
underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the
individual properties of the device are represented as simple files that can be read and written.
Details of the individual slave or master design are hidden behind a consistent interface. The goal is to
provide an easy set of tools for a software designer to create monitoring or control applications. There
are some performance enhancements in the implementation, including data caching, parallel access to bus
masters, and aggregation of device communication. Still the fundamental goal has been ease of use,
flexibility and correctness rather than speed.
EDS00XXOverview
The EDS00XX sensors are a family of devices from EmbeddedDataSystems. Although provisional support for
several types is included, only early EDS0071 has been tested with OWFS.
The sensors all share the same 7E family code. They have the same first memory page layout with a text
tag property that describes them, and a sub-type field giving the particular sensor. The data properties
shown in a directory listing will be specific to the sensor sub-type.EDS0071
The EDS0071(3) is a micro-processor based 1-wire slave made by EDS (Embedded Data Systams). Is uses a
high accuracy and extended range RTD sensor to accurately measure temperatures.
Memory
The EDS00XX sensors are read and controlled by accessing parts of their on-chip memory. Although the raw
memory contents are exposed in the memory and pages fields, all the available functionality is best
accessed by the other fields. In fact, directly changing memory will confuse OWFS.RelayandLED
All the EDS00XX sensors have an LED and optional relay. Both can be controlled either directly, or when
the sensors reaches an alarm state.
Family Code
7E
Humidity
EDS006X/humidityread-only,floating-point
Relative humidity in the 0-100 range (percent). Read every 0.2 seconds.
EDS006X/dew_pointread-only,floating-point
Dew point computed from EDS006X/temperature and EDS006X/humidity computered every 0.2 seconds. Data is a
calculated temperature and is reported in the specified temperature scale. Default Celsius.
EDS006X/heat_indexread-only,floating-point
Heat index computed from EDS006X/temperature and EDS006X/humidity computered every 0.2 seconds. Data is a
calculated temperature and is reported in the specified temperature scale. Default Celsius.
EDS006X/humidexread-only,floating-point
Humidex (popular in Canada) computed from EDS006X/temperature and EDS006X/humidity computed every 0.2
seconds. Data is a percent and reported in the 0-100 range.
Led Light
Found on the EDS006X and EDS007X. Can be controlled by software or the alarm condition.
EDS00XX/LED/controlread-write,unsigned
Set the LED control scheme:
0 alarm control with hysteresis
1 alarm control but need EDS00XX/alarm/clear to unset
2 Control with EDS00XX/LED/state
3 Always off
EDS00XX/LED/stateread-write,yes-no
Turn the LED on or off if the EDS00XX/LED/controlissetto2Light
EDS006X/lightread-only,unsignedinteger
Ambient light in Lux. Measured every 0.2 seconds.
Memory
memoryread-write,binary
96 bytes of memory. Not all is writable. Access to EDS00XX functions is better accomplished through the
data fields, which expose all the chip features.
pages/page.0...pages/page.2pages/page.ALLread-write,binary
Memory is split into 3 pages of 32 bytes each. Only page 2 is writable. ALL is an aggregate of the
pages. Each page is accessed sequentially.
EDS008X/memoryread-write,binary
160 bytes of memory. Not all is writable. Access to EDS008X functions is better accomplished through the
data fields, which expose all the chip features. The EDS008X has more memory than the other chips, so a
separate entry in the sudbirectory makes it available.
EDS008X/pages/page.0-4EDS008X/pages/page.ALLread-write,binary
Memory is split into 5 pages of 32 bytes each. Only page 5 is writable. The EDS008X has more memory than
the other chips, so a separate entry in the sudbirectory makes the extra pages available. ALL is an
aggregate of the pages. Each page is accessed sequentially.
Name
EDS - Embedded Data Systems Sensors
EDS0064
- Temperature
EDS0065
- Temperature and Humidity
EDS0066
- Temperature and Barometric Pressure
EDS0067
- Temperature and Light
EDS0068
- Temperature, Barometric Pressure and Light
EDS0070
- Vibration
EDS0071
- RTD 4-wire temperature
EDS0072
- RTD 3-wire temperature
EDS0080
- 8 Channel Analog Current Input
EDS0082
- 8 Channel Analog Voltage Input
EDS0083
- 4 Channel Analog Current Input
EDS0085
- 4 Channel Analog Voltage Input
EDS0090
- 8 Discrete I/O
Pressure
EDS006X/pressureread-only,floating-point
Ambient pressure, measured every 0.2 seconds. Data in the selected pressure scale (default mBar).
EDS006X/inHgread-only,floating-point
Ambient pressure, measured every 0.2 seconds. Data in the inHg scale.
Relay
Optionally found on the EDS006X and EDS007X. Can be controlled by software or the alarm condition.
EDS00XX/relay/controlread-write,unsigned
Set the relay control scheme:
0 alarm control with hysteresis
1 alarm control but need EDS00XX/alarm/clear to unset
2 Control with EDS00XX/relay/state
3 Always off
EDS00XX/relay/stateread-write,yes-no
Turn the relay on or off if the EDS00XX/relay/controlissetto2See Also
Programsowfs(1)owhttpd(1)owftpd(1)owserver(1)owdir(1)owread(1)owwrite(1)owpresent(1)owtap(1)Configurationandtestingowfs(5)owtap(1)owmon(1)Languagebindingsowtcl(3)owperl(3)owcapi(3)ClocksDS1427(3)DS1904(3)DS1994(3)DS2404(3)DS2404S(3)DS2415(3)DS2417(3)IDDS2401(3)DS2411(3)DS1990A(3)MemoryDS1982(3)DS1985(3)DS1986(3)DS1991(3)DS1992(3)DS1993(3)DS1995(3)DS1996(3)DS2430A(3)DS2431(3)DS2433(3)DS2502(3)DS2506(3)DS28E04(3)DS28EC20(3)SwitchesDS2405(3)DS2406(3)DS2408(3)DS2409(3)DS2413(3)DS28EA00(3)InfernoEmbedded(3)TemperatureDS1822(3)DS1825(3)DS1820(3)DS18B20(3)DS18S20(3)DS1920(3)DS1921(3)DS1821(3)DS28EA00(3)DS28E04(3)EDS0064(3)EDS0065(3)EDS0066(3)EDS0067(3)EDS0068(3)EDS0071(3)EDS0072(3)MAX31826(3)HumidityDS1922(3)DS2438(3)EDS0065(3)EDS0068(3)VoltageDS2450(3)ResistanceDS2890(3)Multifunction(current,voltage,temperature)DS2436(3)DS2437(3)DS2438(3)DS2751(3)DS2755(3)DS2756(3)DS2760(3)DS2770(3)DS2780(3)DS2781(3)DS2788(3)DS2784(3)CounterDS2423(3)LCDScreenLCD(3)DS2408(3)CryptoDS1977(3)PressureDS2406(3)TAI8570(3)EDS0066(3)EDS0068(3)MoistureEEEF(3)DS2438(3)
Set Alarm
Set conditional alarm to trigger if corresponding flag is set. Also must set high and low threshold.EDS00XX/set_alarm/temp_hiEDS00XX/set_alarm/temp_lowEDS006X/set_alarm/humidity_hiEDS006X/set_alarm/humidity_lowEDS006X/set_alarm/dew_point_hiEDS006X/set_alarm/dew_point_lowEDS006X/set_alarm/heat_index_hiEDS006X/set_alarm/heat_index_lowEDS006X/set_alarm/humidex_hiEDS006X/set_alarm/humidex_lowEDS006X/set_alarm/pressure_hiEDS006X/set_alarm/pressure_lowEDS006X/set_alarm/inHg_hiEDS006X/set_alarm/inHg_lowEDS006X/set_alarm/light_hiEDS006X/set_alarm/light_lowEDS0070/set_alarm/vib_hiEDS0070/set_alarm/vib_lowEDS007X/set_alarm/resistance_hiEDS007X/set_alarm/resistance_lowEDS0080/set_alarm/current_hi.[0-7|ALL|BYTE]EDS0080/set_alarm/current_low.[0-7|ALL|BYTE]EDS0082/set_alarm/volts_hi.[0-7|ALL|BYTE]EDS0082/set_alarm/volts_low.[0-7|ALL|BYTE]EDS0083/set_alarm/current_hi.[0-3|ALL|BYTE]EDS0083/set_alarm/current_low.[0-3|ALL|BYTE]EDS0085/set_alarm/volts_hi.[0-3|ALL|BYTE]EDS0085/set_alarm/volts_low.[0-3|ALL|BYTE]read-write,yes-no
Flag to set corresponding out-of-range alarm. "1" turns on flag, and "0" turns off.
Standard Properties
addressr_addressread-only,ascii
The entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-F).
address starts with the family code
raddress is the address in reverse order, which is often used in other applications and labeling.
crc8read-only,ascii
The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of
the unique ID number. Given as upper case hexadecimal digits (0-9A-F).
familyread-only,ascii
The 8-bit family code. Unique to each type of device. Given as upper case hexadecimal digits (0-9A-F).
idr_idread-only,ascii
The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as
upper case hexadecimal digits (0-9A-F).
rid is the id in reverse order, which is often used in other applications and labeling.
locatorr_locatorread-only,ascii
Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical
connections with a unique 1-wire code. If the connection is behind a LinkLocator the locatorwillshowaunique8-bytenumber(16characterhexadecimal)startingwithfamilycodeFE.
If no LinkLocator is between the device and the master, the locator field will be all FF.
rlocator is the locator in reverse order.
present(DEPRECATED)read-only,yes-no
Is the device currently present on the 1-wire bus?
typeread-only,ascii
Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be
distiguished.
Sub-Type
tagread-only,ascii
Text description of the device. Up to 30 characters.
device_typeread-only,ascii
Device name. E.g: "EDS0071"
device_idread-only,unsigned
Number corresponding to the hexadecimal type. E.g:
EDS0071 -> 0x0071 -> 113 in decimal
Synopsis
EmbeddedDataSystems microprocessor-based sensors
Sub-type(all)7E [.]XXXXXXXXXXXX[XX][/[ device_id | device_type | tag ]]
Memory(all)7E [.]XXXXXXXXXXXX[XX][/[ memory | pages/page.[0-2|ALL] ]]
Standard(all)7E [.]XXXXXXXXXXXX[XX][/[ address | crc8 | id | locator | r_address | r_id | r_locator | type ]]
Temperature(EDS0064/5/6/7/8)7E.XXXXXXXXXXXX/EDS006X [/[ temperature | counters/seconds | alarm/temp_[hi|low] | alarm/clear |
set_alarm/temp_[hi|low] | threshold/temp_[hi|low] ]]
Humidity(EDS0065/8)7E.XXXXXXXXXXXX/EDS006X [/[ humidity | humidex | dew_point | heat_index | alarm/humidity_[hi|low] |
alarm/humidex_[hi|low] | alarm/dew_point_[hi|low] | alarm/heat_index_[hi|low] | alarm/clear |
set_alarm/humidity_[hi|low] | set_alarm/humidex_[hi|low] | set_alarm/dew_point_[hi|low] |
set_alarm/heat_index_[hi|low] | threshold/humidity_[hi|low] |
threshold/humidex_[hi|low] | threshold/dew_point_[hi|low] | threshold/heat_index_[hi|low] ]]
BarometricPressure(EDS0066/8)7E.XXXXXXXXXXXX/EDS006X [/[ pressure | inHg | alarm/pressure_[hi|low] | alarm/inHg_[hi|low] | alarm/clear
| set_alarm/pressure_[hi|low] | set_alarm/inHg_[hi|low] | threshold/pressure_[hi|low] |
threshold/inHg_[hi|low] ]]
Light(EDS0067/8)7E.XXXXXXXXXXXX/EDS006X [/[ light | alarm/light_[hi|low] | alarm/clear | set_alarm/light_[hi|low] |
threshold/light_[hi|low] ]]
Vibration(EDS0070)7E.XXXXXXXXXXXX/EDS0070 [/[ vib_level | vib_peak | vib_min | vib_max | counter/seconds |
alarm/vib_[hi|low] | alarm/clear | set_alarm/vib_[hi|low] | threshold/vib_[hi|low] ]]
RTDTemperature(EDS0071/2)7E.XXXXXXXXXXXX/EDS007X [/[ temperature | resistance | raw | delay | user_byte |
calibration/[key|constant] | counter/[seconds|samples] | alarm/temp_[hi|low] | alarm/RTD_[hi_low] |
alarm/clear | set_alarm/temp_[hi|low] | set_alarm/RTD_[hi_low] | threshold/temp_[hi|low] |
threshold/RTD_[hi_low] ]]
AnalogCurrent(EDS0080[0-7]EDS0083[0-3])7E.XXXXXXXXXXXX/EDS0080 [/[ current.[0-7|ALL] | max_current.[0-7|ALL] | min_current.[0-7|ALL] |
threshold/current_hi.[0-7|ALL] | threshold/current_low.[0-7|ALL] | alarm/current_hi.[0-7|ALL|BYTE] |
alarm/current_low.[0-7|ALL|BYTE] | set_alarm/current_hi.[0-7|ALL|BYTE] |
set_alarm/current_low.[0-7|ALL|BYTE] | counter/seconds | memory | pages/page.[0-4|ALL]AnalogVoltage(EDS0082[0-7]EDS0085[0-3])7E.XXXXXXXXXXXX/EDS0082 [/[ volts.[0-7|ALL] | max_volts.[0-7|ALL] | min_volts.[0-7|ALL] |
threshold/volts_hi.[0-7|ALL] | threshold/volts_low.[0-7|ALL] | alarm/volts_hi.[0-7|ALL|BYTE] |
alarm/volts_low.[0-7|ALL|BYTE] | set_alarm/volts_hi.[0-7|ALL|BYTE] | set_alarm/volts_low.[0-7|ALL|BYTE] |
counter/seconds | memory | pages/page.[0-4|ALL]I/O(EDS0090)7E.XXXXXXXXXXXX/EDS009X [/[ input.[0-7|ALL] | counter/[seconds|pulses.[0-7|ALL]|reset.[0-7|ALL|BYTE]] |
output/[set.[0-7|ALL|BYTE]|off.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] |
latch/[state.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] | alarm/[hi.[0-7|ALL]|low.[0-7|ALL]|clear] |
set_alarm/[hi.[0-7|ALL]|low.[0-7|ALL]]LED(all)7E.XXXXXXXXXXXX/EDS00XX/LED/[state|control]relay(all)7E.XXXXXXXXXXXX/EDS00XX/relay/[state|control]Temperature
EDS006X/temperatureread-only,floating-point
Temperature for the EDS006X series of chips. In the -55C to 125C range, with 0.0636C precision. The
temperature is read every second, continually. Data is presented in the specified temperature scale,
Celsius by default.
EDS007X/temperatureread-only,floating-point
Temperature for the EDS007X series of chips. Read using a wide-range precise RTD sensor. Typical range is
-60C to 260C with 0.15C accuracy, although a range of -200C to 850C is possible. The temperature is read
every second unless a longer EDS007X/delay is given. Data is presented in the specified temperature
scale, Celsius by default.
EDS007X/resistanceread-only,floating-point
Actual measured resistance (Ohms) of the RTD element. Useful if the RTD element doesn't conform to the
typical European IEC 60751 standard.
Threshold
High and low range of acceptable sensor readings. Values outside this range will trigger an alarm if the
corresponding EDS00XX/set_alarmflagisset.EDS00XX/threshold/temp_hiEDS00XX/threshold/temp_lowread-write,floating-point
Threshold temperatures in the specified temperature scale. Default Celsius.
EDS006X/threshold/humidity_hiEDS006X/threshold/humidity_lowEDS006X/threshold/dew_point_hiEDS006X/threshold/dew_point_lowEDS006X/threshold/heat_index_hiEDS006X/threshold/heat_index_lowEDS006X/threshold/humidex_hitEDS006X/threshold/humidex_lowread-write,floating-point
Threshold humidity values. Dewpoint and Heatindex are in the specified temperature scale. Default
Celsius.
EDS006X/threshold/pressure_hiEDS006X/threshold/pressure_lowEDS006X/threshold/inHg_hiEDS006X/threshold/inHg_lowread-write,floating-point
Threshold barometric pressure values. Pressure is the specified pressure scale. Default mBar.
EDS006X/threshold/light_hiEDS006X/threshold/light_lowread-write,unsigned
Threshold light (lux) values.
EDS0070/threshold/vib_hiEDS0070/threshold/vib_lowread-write,unsigned
Vibration sensor alarm limits in 0-1023 range.
EDS007X/threshold/resistance_hiEDS007X/threshold/resistance_lowread-write,floating-point
Threshold RTD resistance values (Ohm).
EDS0080/threshold/current_hi.[0-7|ALL]EDS0080/threshold/current_low.[0-7|ALL]EDS0082/threshold/volts_hi.[0-7|ALL]EDS0082/threshold/volts_low.[0-7|ALL]EDS0083/threshold/current_hi.[0-3|ALLEDS0083/threshold/current_low.[0-3|ALL]EDS0085/threshold/volts_hi.[0-3|ALL]EDS0085/threshold/volts_low.[0-3|ALL|]read-write,floating-point
Voltage or current threshold limits
Vibration
EDS0070/vib_levelread_only,unsignedinteger
Vibration registered by sensor (instantaneous value) in 0-1023 range.
EDS0070/vib_peakread_only,unsignedinteger
Vibration registered by sensor (highest recent value -- slowly decays) in 0-1023 range.
EDS0070/vib_minread_only,unsignedinteger
Vibration registered by sensor (lowest value) in 0-1023 range.
EDS0070/vib_maxread_only,unsignedinteger
Vibration registered by sensor (highest value) in 0-1023 range.
Voltage
The EDS0082 and EDS0085 measure voltage in the 0-10V range, with upper and threshold limits and the
ability to set an alarm and independently trigger a relay if the value is out of range.
EDS0082/volts.[0-7|ALL]EDS0085/volts.[0-3|ALL]read-only,floatingpoint
Current voltage level. (0-10V)
EDS0082/max_volts.[0-7|ALL]EDS0085/max_volts.[0-3|ALL]EDS0082/min_volts.[0-7|ALL]EDS0085/min_volts.[0-3|ALL]read-only,floatingpoint
Maximum and minimum voltage readings since last alarm/clear command.