-p get PathRecord info
-N get NodeRecord info
-D,--list
get NodeDescriptions of CAs only
-S get ServiceRecord info
-I get InformInfoRecord (subscription) info
-L return the Lids of the name specified
-l return the unique Lid of the name specified
-G return the Guids of the name specified
-O return the name for the Lid specified
-U return the name for the Guid specified
-c get the SA's class port info
-s return the PortInfoRecords with isSM or isSMdisabled capability mask bit on
-g get multicast group info
-m get multicast member info. If a group is specified, limit the output to the group specified and
print one line containing only the GUID and node description for each entry. Example: saquery -m
0xc000
-x get LinkRecord info
--src-to-dst<src:dst>
get a PathRecord for <src:dst> where src and dst are either node names or LIDs
--sgid-to-dgid<sgid:dgid>
get a PathRecord for sgid to dgid where both GIDs are in an IPv6 format acceptable to inet_pton(3)--smkey<val>
use SM_Key value for the query. Will be used only with "trusted" queries. If non-numeric value
(like 'x') is specified then saquery will prompt for a value. Default (when not specified here or
in /etc/infiniband-diags/ibdiag.conf) is to use SM_Key == 0 (or "untrusted")
-K,--show_keys
show security keys (mkey, smkey, etc.) associated with the request.
--slid<lid> Source LID (PathRecord)
--dlid<lid> Destination LID (PathRecord)
--mlid<lid> Multicast LID (MCMemberRecord)
--sgid<gid> Source GID (IPv6 format) (PathRecord)
--dgid<gid> Destination GID (IPv6 format) (PathRecord)
--gid<gid> Port GID (MCMemberRecord)
--mgid<gid> Multicast GID (MCMemberRecord)
--reversible Reversible path (PathRecord)
--numb_path Number of paths (PathRecord)
--pkeyP_Key(PathRecord,MCMemberRecord).Ifnon-numericvalue(like'x')
is specified then saquery will prompt for a value
--qos_class QoS Class (PathRecord)
--sl Service level (PathRecord, MCMemberRecord)
--mtu MTU and selector (PathRecord, MCMemberRecord)
--rate Rate and selector (PathRecord, MCMemberRecord)
--pkt_lifetime Packet lifetime and selector (PathRecord, MCMemberRecord)
--qkeyQ_Key(MCMemberRecord).Ifnon-numericvalue(like'x')isspecified
then saquery will prompt for a value
--tclass Traffic Class (PathRecord, MCMemberRecord)
--flow_label Flow Label (PathRecord, MCMemberRecord)
--hop_limit Hop limit (PathRecord, MCMemberRecord)
--scope Scope (MCMemberRecord)
--join_state Join state (MCMemberRecord)
--proxy_join Proxy join (MCMemberRecord)
--service_id ServiceID (PathRecord)
Supported query names (and aliases):
ClassPortInfo (CPI)
NodeRecord (NR) [lid]
PortInfoRecord (PIR) [[lid]/[port]/[options]]
SL2VLTableRecord (SL2VL) [[lid]/[in_port]/[out_port]]
PKeyTableRecord (PKTR) [[lid]/[port]/[block]]
VLArbitrationTableRecord (VLAR) [[lid]/[port]/[block]]
InformInfoRecord (IIR)
LinkRecord (LR) [[from_lid]/[from_port]] [[to_lid]/[to_port]]
ServiceRecord (SR)
PathRecord (PR)
MCMemberRecord (MCMR)
LFTRecord (LFTR) [[lid]/[block]]
MFTRecord (MFTR) [[mlid]/[position]/[block]]
GUIDInfoRecord (GIR) [[lid]/[block]]
SwitchInfoRecord (SWIR) [lid]
SMInfoRecord (SMIR) [lid]
PortSelectionflags-C,--Ca<ca_name> use the specified ca_name.
-P,--Port<ca_port> use the specified ca_port.
LocalportSelection
Multiple port/Multiple CA support: when no IB device or port is specified (see the "local umad
parameters" below), the libibumad library selects the port to use by the following criteria:
1. the first port that is ACTIVE.
2. if not found, the first port that is UP (physical link up).
If a port and/or CA name is specified, the libibumad library attempts to fulfill the user request, and
will fail if it is not possible.
For example:
ibaddr # use the first port (criteria #1 above)
ibaddr -C mthca1 # pick the best port from "mthca1" only.
ibaddr -P 2 # use the second (active/up) port from the first available IB device.
ibaddr -C mthca0 -P 2 # use the specified port only.
Debuggingflags-d raise the IB debugging level. May be used several times (-ddd or -d -d -d).
-e show send and receive errors (timeouts and others)
-h,--help show the usage message
-v,--verbose
increase the application verbosity level. May be used several times (-vv or -v -v -v)
-V,--version show the version info.
Configurationflags-t,--timeout<timeout_ms> override the default timeout for the solicited mads.
--outstanding_smps,-o<val>
Specify the number of outstanding SMP's which should be issued during the scan
Default: 2
--node-name-map<node-name-map> Specify a node name map.
This file maps GUIDs to more user friendly names. See FILES section.
--config,-z<config_file> Specify alternate config file.
Default: /etc/infiniband-diags/ibdiag.conf