powercap-info - get information from the Linux power capping framework
Contents
Bugs
Report bugs upstream at <https://github.com/powercap/powercap>
Description
Prints configurations for powercap control types.
Output can be filtered by specifying a control type NAME and OPTION flags.
A control type NAME must not be empty or contain a '.' or '/'.
Examples
powercap-info
Print all zones for all control types.
powercap-infointel-rapl
Print all zones for the intel-rapl control type.
powercap-infointel-rapl-z0
Print only zone 0 for the intel-rapl control type.
powercap-infointel-rapl-z0:1
Print zone 0, subzone 1 for the intel-rapl control type.
powercap-infointel-rapl-z0-c1
Print zone 0, constraint 1 for the intel-rapl control type.
powercap-infointel-rapl-z0-j
Print the energy counter for zone 0 for the intel-rapl control type.
powercap-infointel-rapl-z1:0-c0-l
Print the power limit for zone 1, subzone 0, constraint 0 for the intel-rapl control type.
Files
/sys/devices/virtual/powercap/*/sys/class/powercap/*Name
powercap-info - get information from the Linux power capping framework
Options
-h,--help
Prints the help screen
-v,--verbose
Print errors when files cannot be read
-p,--control-type=NAME
Deprecated, provide NAME as the first positional argument instead.
All remaining options below require a control type NAME:
-z,--zone=ZONE(S)
The zone/subzone numbers in the control type's powercap tree (control type's root by default).
Separate zones/subzones with a colon. E.g., for zone 0, subzone 2:
-z0:2
Ending with a colon prevents output for subzones. E.g., for zone 0, but not subzones:
-z0:-c,--constraint=CONSTRAINT
The constraint number
All remaining options below are mutually exclusive:
-E,--enabled
Print control type enabled/disabled status
-n,--nzones
Print the number of zones (control type's root by default; within the -z/--zone level, if set)
The following are zone-level arguments and require -z/--zone:
-N,--nconstraints
Print the number of zone constraints
-j,--z-energy
Print zone energy counter
-J,--z-max-energy-range
Print zone maximum energy counter range
-w,--z-power
Print zone current power
-W,--z-max-power-range
Print zone maximum current power range
-e,--z-enabled
Print zone enabled/disabled status
-x,--z-name
Print zone name
The following are constraint-level arguments and require -z/--zone and -c/--constraint:
-l,--c-power-limit
Print constraint power limit
-s,--c-time-window
Print constraint time window
-U,--c-max-power
Print constraint maximum allowed power
-u,--c-min-power
Print constraint minimum allowed power
-T,--c-max-time-window
Print constraint maximum allowed time window
-t,--c-min-time-window
Print constraint minimum allowed time window
-y,--c-name
Print constraint name
Remarks
Some fields are optional and/or may require administrative (super-user) privileges to read.
Fields will only be printed if they are available and readable, unless -v/--verbose is set.
If no subzone/constraint-specific outputs are requested, all available zones and constraints will be
shown.
Energy units: microjoules (uJ)
Power units: microwatts (uW)
Time units: microseconds (us)
See Also
powercap-set(1) powercap 2021-12-12 POWERCAP-INFO(1)
Synposis
powercap-info [NAME [OPTION]...] [-hv]